RIC-E1 Installation and Operation Manual

Chapter 1 Introduction

Technical Specifications

1-5

Diagnostics

Complies with ITU V.54 (loop 3)

Local Loopback

Activated by:
• Internal jumper (RIC-E1)
• Front panel pushbutton (RIC-E1/R)
• DTE circuit 141 for V.35, RS-530 and V.36

Power

AC Source

100 to 240 VAC (± 10%), 50 or 60 Hz

DC Source

• -48 VDC (-36 to -72 VDC)
• 24 VDC (18 to 36 VDC)

Power Consumption

• Standalone: 3W, max
• RIC-E1/R: 5.2W

Fuses

Standalone RIC-E1: 250 mA 250V slowblow
RIC-E1/R: 500 mA 250V slowblow

Physical

RIC-E1

Height

39.5 mm / 1.5 in

Width

190 mm / 7.4 in

Depth

160 mm / 6.2 in

Weight

0.6 kg / 1.3 lb

RIC-E1/R

Fits one slot in the ASM-MN-214 card cage

Environment

Temperature

0–50°C (32–122°F)

Humidity

Up to 90%, non-condensing