Setting the dip switches – RAD Data comm E1 Interface Converter RIC-E1 User Manual

Page 55

Advertising
background image

RIC-E1 Installation and Operation Manual

Appendix C IR-ETH/V Interface Module

Installation and Operation

C-5

Setting the DIP Switches

Configure the IR-ETH/V module by setting the DIP switches SW1 and SW2 in
accordance with

Figure C-4

,

Table C-2

and

Table C-3

.

Reset RIC-E1 for changes in the flow control and LAN filtering switches to take effect.

Table C-2. DIP SW1 Switch Settings

Section Name

Description

Possible Settings

Factory Setting

1 MDI

Enables

or

disables

automatic MDI/MDIX

crossover

ON

Automatic MDI/MDIX crossover

is disabled

OFF

– Automatic MDI/MDIX

crossover is enabled


OFF

2, 3

NC

FLC

Enables or disables flow

control (full duplex) /
backpressure (half

duplex)

4

Note: Flow Control (full duplex) is active

only if autonegotiation is enabled

ON

– Flow control/Backpressure is

enabled

OFF

Flow control/Backpressure is

disabled

ON

5 FIL

Enable or disable LAN
filtering

ON

– LAN filtering is disabled

OFF

– LAN filtering is enabled


OFF

6 FP Enable or disable fault

propagation

ON

– Fault propagation is disabled

OFF

– Fault propagation is enabled

ON

Note: When fault propagation is enabled, the LAN interface shuts down if a failure is detected on the E1 line.

When fault propagation is disabled, the link integrity is not influenced by the E1 behavior.

7, 8

NC

Sections 2, 3, 7, and 8 of the SW1 DIP switch are factory-set and must not be
moved by the user.

Table C-3. DIP Switch SW2 Settings

Section Name

Description

Possible Settings

Factory Setting

1

100

Selects the LAN speed

ON

– LAN speed is set to 10 Mbps

OFF

– LAN speed is set to 100 Mbps


OFF

2

AN

Controls the LAN
autonegotiation

ON

– LAN autonegotiation is disabled

OFF

– LAN autonegotiation is enabled


OFF

3

FDX

Selects the LAN duplex

mode

ON

– LAN half duplex mode

OFF

– LAN full duplex mode


OFF

4, 5, 6

NC

Sections 4, 5, and 6 of the SW2 DIP switch are factory-set and must not be

moved by the user.

When autonegotiation is enabled, LAN speed and LAN duplex mode are

configured automatically (sections 1 and 3 are disabled).

Note

Notes

Note

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com