RAD Data comm ASMi-52 User Manual

Page 125

Advertising
background image

Installation and Operation Manual

Chapter 6 Troubleshooting and Diagnostics

ASMi-52 Ver. 2.5

Testing ASMi-52

6-21

To run the local loopback:
1. From the Main menu, select Diagnostics.

The Diagnostics menu is displayed (see

Figure 6-22

).

2. From the Diagnostics menu, select:

Local Test

to run the LLB on the local ASMi-52

Remote Test

to run the LLB on the remote ASMi-52.

The Local/Remote Test menu appears (see

Figure 6-23

).

3. Select LLB.

The LLB value in parenthesis changes to ON. Also, an additional
parameter, Loop Timeout, is displayed for the local ASMi-52.

4. Select Loop Timeout, if you want to set loopback timeout (in minutes).

The Loop Timeout value changes.

Avoid setting timeout to 0 as local control is lost during LLB. 0=Forever

5. Once you selected the loopback timeout, select Save to activate the LLB.

The LLB is initiated. The TST indicator lights up and the ASMi-52 units lose
synchronization.

ASMi-52

Diagnostics
5. Local Test

>

6. Remote Test

>

7. Repeater Test

>

>


ESC-previous menu ; !–main menu ; &–exit terminal

Figure 6-22. Diagnostics Menu

ASMi-52

Local Test or Remote Test

LLB from DTE: OFF

RLB from DTE: OFF

1. Bert

>

2. LLB (ON)
3. Loop Timeout (min)(0-4095) ...(5)
4. LEDs test
5. Clear all
6. Save

>

ESC-previous menu ; !–main menu ; &–exit; @-scroll

Figure 6-23. Local/Remote Test Menu

Note