Model number description – Trane RT-PRC007-EN User Manual

Page 14

Advertising
background image

RT-PRC007-EN

14

Model
Number
Description

YC

D

480

A

4

H

A

1

A

4

F

D

1

A

0

0

0

0

0

0

0

0

0

0

0 0

5

12

3

456

7

8

9

10 11

12 13

14

15 16 17

18 19 20 21 22 23 24

25 26

27 28 29

KW

Tons

Voltage

36

54

72

90

108

27½ to 35

240

x

x

480

x

x

x

x

600

x

x

x

40 and 50

240

x

480

x

x

x

x

600

x

x

x

x

Digit 1, 2 — Unit Function

TC = DX Cooling, No Heat
TE = DX Cooling, Electric Heat
YC = DX Cooling, Natural Gas Heat

Digit 3 — Unit Airflow Design

D = Downflow Configuration
H = Horizontal Configuration

Digit 4, 5, 6 — Nominal Cooling Capacity

330 = 27½ Tons
360 = 30 Tons
420 = 35 Tons
480 = 40 Tons
600 = 50 Tons

Digit 7 — Major Development Sequence

A = First

Digit 8 — Power Supply (See Note 1)

E = 208/60/3
F = 230/60/3
4 = 460/60/3
5 = 575/60/3

Digit 9 — Heating Capacity (See Note 4)

0 = No Heat (TC only)
L = Low Heat (YC only)
H = High Heat (YC only)
Note: When second digit is “E” for Electric
Heat, the following values apply in the ninth
digit.
A = 36 KW
B = 54 KW
C = 72 KW
D = 90 KW
E = 108 KW

Digit 10 Design Sequence

A = First

Digit 11 — Exhaust

0 = None
1 = Barometric Relief
(Available w/Economizer only)
2 = Power Exhaust Fan
(Available w/Economizer only)

Digit 12 — Filter

A = Standard 2” Throwaway Filters
B = High Efficiency 2” Throwaway Filters
C = High Efficiency 4” Throwaway Filters

Digit 13 — Supply Fan Motor, HP

1 = 7.5 Hp Std. Eff.
2 = 10 Hp Std. Eff.
3 = 15 Hp Std. Eff.
4 = 20 Hp Std. Eff.
5 = 7.5 Hp Hi. Eff.
6 = 10 Hp Hi. Eff.
7 = 15 Hp Hi. Eff.
8 = 20 Hp Hi. Eff.

Digit 14 — Supply Air Fan Drive
Selections (See Note 3)

A = 550 RPM

H = 500 RPM

B = 600 RPM

J = 525 RPM

C = 650 RPM

K = 575 RPM

D = 700 RPM

L = 625 RPM

E = 750 RPM

M = 675 RPM

F = 790 RPM

N = 725 RPM

G = 800 RPM

Digit 15 — Fresh Air Selection

A = No Fresh Air
B = 0-25% Manual Damper
C = 0-100% Economizer, Dry Bulb Control
D = 0-100% Economizer, Reference

Enthalpy Control

E = 0-100% Economizer, Differential

Enthalpy Control

F = “C” Option and Low Leak Fresh

Air Damper

G = “D” Option and Low Leak Fresh

Air Damper

H = “E” Option and Low Leak Fresh

Air Damper

Digit 16 — System Control

1 = Constant Volume
2 = VAV Supply Air Temperature Control

w/o Inlet Guide Vanes

3 = VAV Supply Air Temperature Control

w/Inlet Guide Vanes

4 = VAV Supply Air Temperature Control

w/Variable Frequency Drive w/o Bypass

5 = VAV Supply Air Temperature Control

w/Variable Frequency Drive and Bypass

Note: Zone sensors are not included with
option and must be ordered as a separate
accessory.

Digit 17 - 29 — Miscellaneous
A = Service Valves (See Note 2)
B = Through the Base Electrical Provision
C = Non-Fused Disconnect Switch with

External Handle

D = Factory-Powered 15A GFI

Convenience Outlet and Non-Fused
Disconnect Switch with
External Handle

E = Field-Powered 15A GFI

Convenience Outlet

F = ICS Control Option — Trane

Communication Interface, Supply Air
Sensing and Clogged Filter Switch

G = Ventilation Override
H = Hinged Service Access
J = Condenser Coil Guards
K = LonTalk Communication Interface
L = Special
M = Stainless Steel Drain Pans
N = Black Epoxy Coated Condenser Coil

5. The service digit for each model number contains 29 digits; all 29 digits must be referenced.

Note:
1. All voltages are across the line starting only.
2. Option includes Liquid, Discharge, Suction Valves.
3. Supply air fan drives A thru G are used with 27½-35 ton units only and drives H thru N are used with 40 & 50

ton units only.

4. Electric Heat KW ratings are based upon voltage ratings of 240/480/600 V. Voltage offerings are as follows (see

table PD-9 for additional information):