Instruction Classification

4-31

Assembly Language Instructions

between the accumulator and the MR, SV, or PH register. As with all accumula-
tor referenced instructions, string operations are possible as well as premodi-
fication of one of 4 indirectly referenced accumulator pointer registers (AP).

Table 4–19. Class 3 Instruction Encoding

Bit

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Class 3

1

1

1

0

0

next A

A

n

C3

0

A~

~A

Table 4–20. Class 3 Instruction Description

C3

Mnemonic

Description

0

0

0

0

0

NEGAC A

n[~], An[~] [, next A]

NEGACS A

n[~], An[~]

Store the 2’s complement of the source accumulator
(A~=0 or 1) to the destination accumulator (~A=0 or 1).
ALU status is modified.

0

0

0

0

1

NOTAC A

n[~], An[~] [, next A]

NOTACS A

n[~], An[~]

Place the 1’s complement of the source accumulator
(A~=0 or 1) into the destination accumulator (~A=0 or 1).
ALU status is modified.

0

0

0

1

0

MOV A

n[~], *An[~] [, next A]

MOVS A

n[~], *An[~]

Look up a value in program memory addressed by
accumulator (A~=0 or 1). Place the lookup value into the
accumulator (~A=0 or 1). The lookup address is
post–incremented in the DP register. ALU status is
modified based on the lookup value.

0

0

0

1

1

ZAC A

n[~] [, next A]

ZACS A

n[~]

Zero accumulator (~A=0 or 1). ALU status is modified.

0

0

1

0

0

SUB A

n[~], An, An~ [, next A]

SUB A

n[~], An~, An [, next A]

SUBS A

n[~], An, An~

SUBS A

n[~], An~, An

Subtract offset accumulator from accumulator (A~=0) or
subtract accumulator from offset accumulator (A~=1).
Store the result in accumulator (~A=0 or 1). ALU status is
modified.

0

0

1

0

1

ADD A

n[~], An~, An [, next A]

ADDS A

n[~], An~, An

Add accumulator to offset accumulator and store result to
accumulator (~A=0 or 1). ALU status is modified.

0

0

1

1

0

SHLAC A

n[~], An[~] [, next A]

SHLACS A

n[~], An[~]

Shift accumulator left 1 bit and store the result into
accumulator(~A=0) or offset accumulator (~A=1). The
LSB is set to zero and the MSB is stored in a carryout
status bit. ALU status is modified.

0

0

1

1

1

MOV A

n, An~ [, next A]

MOVS A

n, An~

Copy accumulator (A~=0 or 1) to accumulator (~A=0 or 1).