Dataport configuration – TANDBERG D12155-10 User Manual

Page 87

Advertising
background image

TANDBERG Videoconferencing System

87

Advanced use

Dataport configuration

The system provides two standard RS232 serial ports to allow a computer to be connected for data transfer and
control purposes.

Dataport 1

If you wish to connect a PC to Dataport 1, you must ensure that the PC and the system are identically
configured. The available settings are:

Dataport 1 supports 4 different modes:

Data mode
Provides a transparent data channel. This
channel can be used for many different
purposes such as file transfer, application
sharing and more. When using this mode, it is
necessary to have a TANDBERG system at
the far end.

Control mode
The control interface provided by the Dataport
supports a subset of the Hayes command set
as well as a comprehensive set of system
specific commands.

This mode maintains communication with the Dataport’s command interpreter at all times. All features available
from the hand-held remote control can be accessed through the dataport.

Modem
Allows you to control the system externally via a PC as in Control Mode. Once a call is established, Dataport 1
will automatically switch to Data mode. When the call disconnects, Dataport 1 switches back to Control Mode.

T.120
Provides a data channel supporting the T.120 standard for data communication. Using T.120 software on your PC,
you can communicate with other T.120 systems using your PC and your system.

NOTE

W

HEN

CONNECTING

TO

A

PC

THE

CONNECTING

CABLE

MUST

BE

A

STRAIGHT

THROUGH

RS232

CABLE

.