Extended "at&" command set – ZyXEL Communications Omni TA128 User Manual
Page 113
![background image](/manuals/227513/113/background.png)
101
Extended "AT&" Command Set
Command Options Function and Description
Ref.
&Cn
Carrier Detect (CD) options
&C1 * CD tracks presence of carrier
All other values are invalid
&Dn
Data Terminal Ready (DTR)
options.
&D2 * 108.2, Data Terminal Ready, DTR
OFF causes the TA to hang up.
All other values are invalid
&En
B channel line speed for ISDN
data call
S128.2
&E0 *
64Kbps
&E1
56Kbps (Default for American
ISDN)
&F
Load factory settings to RAM as
the active configuration.
&Hn
Data flow control, DTE/DCE.
&H3 * Hardware (CTS/RTS) flow control
All other values are invalid
&On
Set default call type for
conventional dialing commands
&O2 * ATDs, ATDPs, and ATDTs
default to make ISDN data calls
All other values are invalid
&Sn
Data Set Ready (DSR) function
selection.
&S0 *
DSR overridden, DSR always ON.
All other values are invalid
&Vn
View profile settings.
&V0
View current active settings.
&V5
View factory default settings.