Able, Land, Nstallation – B&B Electronics ZXT9-RM-KIT - Manual User Manual

Page 14: Atertight, Hreaded, Onduit, Escription

Advertising
background image

Document Number: pnZXTxRM-0712m

Page
14


3.2.2 Cable Gland Installation

1. The cable gland will accept cable diameters from 0.236 to 0.472 inches (5.99 to 11.99

mm).

2. Insert the Non-tapered end of the Body (D) through the conduit knock-out on the radio

modem enclosure.

3. Place the Gasket around the body on the outside of the enclosure.
4. Thread the Hex Nut onto the Body from the inside of the enclosure.
5. Place the Cable Nut onto the cable being careful to position the threaded side so that

it can be attached to the Cable Body.

6. Tighten the Cable Nut. This will cause the tapered end of the Cable Body to

compress, ensuring a water-tight seal.

3.3 Watertight Threaded Conduit Hub

Unused conduit openings: Class 1 Division 2 installation requires a UL
Recognized conduit plug (UL Category Code QCRV2) be used when a conduit
opening is not being used.

3.3.1 Description


Another method to bring a cable into the enclosure is to use the water tight threaded
conduit hub. It is used to secure threaded half inch rigid service entrance conduit. It
consists of a Body, Nut, and Gasket.


Figure 3-5

½ Inch Threaded Conduit Hub

Figure 3-6

½ Inch Threaded Conduit Hub

Advertising