1-8 Introduction

H-335

1.9 Installing the H-335 and setting the mechanical sensor offset

The tilt sensor in the H-335 has a physical ±40 calibrated range. This allows sufficient dynamic range to

measure a gate which opens up to 80 . To work properly, the sensor must be mechanically adjusted during

installation to preserve the available physical dynamic range. This is done by loosening two screws and

rotating the internal sensor assembly. The mechanical offset adjustments are made while monitoring the

SensorAngle parameter. This is the raw sensor reading with no adjustment for slope or offset. The

UserAngle parameter is processed with a slope and offset term to produce the more useful 0.0 to +80.0

reading for the data recorder.

With the gate closed the mechanical offset must be set near (but not beyond) one end of the sensor’s

measurement range. The proper setting depends on which gate arm the H-335 is installed and which side of

the I-beam the H-335 is mounted (see Figure 2). For example; with a gate which can open up to 70 and

which the inclinometer rotates clockwise (while facing the H-335 cover) as the gate opens, the sensor

should be rotated until SensorAngle reads ~ -35 . When this gate is fully open the raw SensorAngle will

read +35 . With the same gate but with the inclinometer installed such that it rotates counter-clockwise

(while facing the H-335 cover) as the gate opens, the sensor must be mechanically adjusted to +35 . When

this gate is fully open the raw SensorAngle will read -35 .

The H-335 fiberglass enclosure can be installed in any

position in the plane of rotation. If possible, locate the

connector on the bottom to prevent water from standing

on the connector. The internal ceramic sensor element

is symmetrical and will still make measurements if

installed upside down. However, if the sensor is upside

down, the calibration will be invalid, the slope will be

wrong and the output data confusing. Check to make

certain the wires exit the red plastic cover at the 2:00

o’clock position when the gate is in the center of its

travel arc.