2-12 SDI-12 Command and Response Protocol

H-335

2.12 Extended “XTEST” and “XRAW” Commands

These commands are used for installation or production testing and requires the use of a H-419

Sidekick interface and a PC. These commands causes the H-335 to transmit unsolicited real-time

data for testing purposes. This is not compliant with the SDI-12 specification and is not used with

data loggers.

To activate the test mode, first send the command “aXTEST!” or “aXRAW” from the PC. The H-

335 will automatically display a new line of data about once per second. This test mode may be used

to help troubleshoot the installation by providing a continuous readout of sensor data. The test mode

is exited by sending any new command on the SDI-12 bus (a BREAK terminates the test). It may

take a few tries to exit if the command is sent at the same time data is being sent from the H-335.

Removing power from the H-335 also causes it to exit this mode.

“aXTEST” displays the following data:

a

(sensor address)

SensorAngle

(degrees)

Example of the XTEST test display:

a +1.200

a +1.500

a +1.700

a +1.900

etc.

“aXRAW” displays the following data:

a

(sensor address)

Gate Arc Length

(feet, meters etc.)

Gate Height

(feet, meters etc.)

User Angle

(degrees)

Sensor Angle

(degrees)

Raw Positive A/D count

(±8192)

Raw Negative A/D count

(±8192)

Raw Positive - Negative A/D count (±16384)

Sensor Temperature.

( C)

Example of the “XRAW” test display:

a +1.200 +.1.103 +4.565 -32.231 -2639 +5836 +8475 +23.52

a +1.500 +.1.213 +5.183 -31.613 -2234 +5835 +8069 +23.51

a +1.700 +.1.451 +5.397 -31.399 -2656 +5848 +8504 +23.54

a +1.900 +.1.602 +5.565 -31.231 -2678 +5786 +8464 +24.03