Appendix a specifications, H-335 – Xylem H-335 User Manual

Page 31

Advertising
background image

Appendix A

Specifications

H-335

Appendix A Specifications A-1

General

Sensor:

ceramic, single axis, linear, wide angle

Type:

electrolytic fluid

Range:

-40 to +40 (80 total)

Resolution:

0.005

Accuracy:

+-0.03 (absolute over full range)

(0.25 inch gate height with 36' gate radius)

(0.13 inch gate height with 20' gate radius)

Offset Adjust:

software command with gate against sill

Temperature:

-30 to +50 C (calibrated range)

Settling Time:

<300ms

SDI-12 Measurement Time: 2 Sec

SDI-12 Output

Baud Rate:

1200

Protocol:

SDI-12, 7-bit even parity, 1 stop bit

Output Voltage Levels:

minimum high level:

3.5 volts

maximum low level:

0.8 volts

maximum cable length: 250 ft.

SDI-12 Output Data Parameters:

1 - Gate Arc Length (feet, inches, meters, etc.)

2 - Gate Height (feet, inches, meters etc.)

3 - Gate Angle (degrees)

4 - Temperature ( C )

Power Requirements

Voltage Input:

10.0 to 16.0 Volts DC

Current

Measuring:

30 mA

Standby

20 mA typical

Environmental

Operating Temperature: -30 to +60 C

Storage Temperature:

-50 to +70 C

Mechanical

Material:

40% graphite filled fiberglass

Size:

4.76" x 4.76" x 2.5" high

Rating:

NEMA 4X, 6

Connector:

liquid tight strain relief fitting

.08" to .24" dia cable

Beam Clamp:

2-Inch max I-beam thickness.

Mount fixture is adjustable in

3-axis to compensate for camber

in the gate structure.

Cable:

not included

Recommended Cable:

polyurethane or similar, rated for

water immersion and sunlight

resistance.

Warranty

The

W

ATER

LOG

®

H-335 is warranted against defects

in materials and workmanship for one year from date

of shipment.

Advertising