7

Parameters

610.00260.40.000 · 05.2014

42

/

74

© Gardner Denver Deutschland GmbH

1,130

Setpoint source

Unit: integer

Relationship to
parameter:
3,062 – 3,069

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 10

Def: 1

Specifies the source from which the setpoint is to be read.
0 = internal potentiometer
1 = analogue input 1
2 = analogue input 2
3 = MANUAL CONTROL UNIT MMI/PC
4 = SAS
6 = motor potentiometer
7 = total analogue inputs 1 and 2
8 = PID fixed setpoints (3,062 - 3,069)
9 = fieldbus
10 = integrated soft PLC

1,131

Software release

Unit: integer

Relationship to
parameter:
1,132
1,150
2,050
4,030
4,050

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 13

Def: 0

WARNING! Depending on the change made, the motor

may start to run directly.
Selection of the source for the control release.
0 = digital input 1
1 = digital input 2
2 = digital input 3
3 = digital input 4
4 = analogue input 1 (must be selected in parameter 4,030)
5 = analogue input 2 (must be selected in parameter 4,050)
6 = field bus
7 = SAS
8 = digital input 1 right / digital input 2 left
1,150 must be set to "0"
9 = autostart
10 = integrated soft - PLC
11 = fixed frequency inputs (all inputs that have been selected in
parameter 2,050)
12 = internal potentiometer
13 = membrane keyboard (start & stop buttons)
If the hardware release and a setpoint are applied, the motor
may start to run directly!
This cannot be prevented even with parameter 1,132.