B&K Precision XLN60026 - Manual User Manual

Page 148

Advertising
background image

52

Example 1:

To output the waveform shown above, users may edit the program through
the following commands:

PROG 1

Choose program number

PROG:CLE

Clear program 1 data

PROG:REP 0

No repeat (repeat one time for “1”)

PROG:TOTA 8

Set program 1 to have 8 steps in total

PROG:STEP 1

Following 3 settings are for step 1

PROG:STEP:CURR 2

Set output current to 2 ampere

PROG:STEP:VOLT 50

Output voltage is set to 50 volts

PROG:STEP:ONT 0.5

Output ON time is set to 0.5 sec

PROG:STEP 2

Following 3 settings are for step 2

PROG:STEP:CURR 2

PROG:STEP:VOLT 100

PROG:STEP:ONT 0.5

PROG:STEP 3

Choose step 3

PROG:STEP:CURR 2

PROG:STEP:VOLT 150

PROG:STEP:ONT 0.5

PROG:STEP 4

Choose step 4

PROG:STEP:CURR 2

PROG:STEP:VOLT 200

PROG:STEP:ONT 0.5

PROG:STEP 5

Choose step 5

PROG:STEP:CURR 2

PROG:STEP:VOLT 150

Advertising