51

SYSTEM CONTROL COMMAND:

Command

Description

==================================================
CADR

followed by address, which can be 1 to 30 and

is used to access the power supply

CCLS

Clear status

CRST

Reset command. Brings the power supply to a

known state

CIDN?

Returns the power supply model identification

CREV?

Returns the firmware version

CSN?

Returns the serial number

CST?

Returns the device status

CCLR?

Clear protect

==================================================
OUTPUT CONTROL COMMAND:

Command

Description

==================================================
CPV

Sets the output voltage value in Volts

CPV?

Reads the output voltage setting

CMV?

Reads the actual output voltage

CPC

Sets the output current value in Amperes

CPC?

Reads the output current setting

CMC

Reads the actual output current

CDVC?

Display voltage and current data

COUT

Turns the output to ON or OFF

COUT?

Returns the output On/Off status

COV

Sets the OVP level

COV?

Returns the OVP setting level

COVP

Sets the OVP on/off

COVP?

Returns the OVP on/off

COC

Sets the OCP level