Chapter 3 – Printer Operation

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

H

Raise the cover assembly then

proceed according to the media

type:

Die-cut – Remove a label or two

from the liner then position the

liner in the Media Sensor.

Notched – Position the Media in

the Media Sensor under the notch.

Reflective – Position the Media in

the Media Sensor under the black

mark.

TRAN SENSOR GAIN

09

31

(0 - 31)

(1) Do not position the Media

Sensor under a perforation; and

if using preprinted media, ensure

the label area placed over the

sensor is free of text, graphics,

lines, etc.

(2) Do not move the Media

Sensor after this step.

I

Lower and latch the Cover

Assembly.


Using the

or

button, set the

Gain Number to 0.

Record the reading as a TOF Value

for Gain Number 0 in the table.

TRAN SENSOR GAIN

248

0

(0 - 31)

This is the TOF Value for a gain

setting of 0, where “248”

represents the current sensor

reading.


Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248
01 250

02 248

… …

31 09