CognitiveTPG A798 User Manual

Page 72

Advertising
background image

Chapter 4: Programming Commands

72

Revision C 12/09

A798-PG00001C

Flash memory user sector status (n = 4 or n = 52)
Bit Off/On Hex Decimal Status for transmit status

0

Undefined. Fixed to off.

1

Undefined. Fixed to off.

2

Off

00

0

User data storage write successful

On

04

4

User data storage write failed, specified area not erased.

3

Off

00

0

Flash logo area adequate, definition stored

On

08

8

Flash logo area not adequate

4

Off

00

0

Not used. Fixed to off.

5

Off

00

00

No thermal user-defined characters

written to flash.

On

20

32

Thermal user-defined characters written to flash.

6

Off

00

0

Not used. Fixed to off.

7

Undefined.

Exceptions

When n is out of the specified range, the command is ignored.

Send printer software version

ASCII

US V

Hexadecimal 1F 56

Decimal

31 86

The printer returns 8 bytes containing the boot and flash software version. The first 4 bytes returned are an ASCII string for
the boot version.
The second 4 bytes are an ASCII string for the flash version. Example: For 1.234.56 (8 bytes), the boot version is 1.23 and
the flash version is 4.56.