Flash memory user sector status (n = 4 or n = 52)
Bit Off/On Hex Decimal Status for transmit status
0
–
–
–
Undefined. Fixed to off.
1
–
–
–
Undefined. Fixed to off.
2
Off
00
0
User data storage write successful
On
04
4
User data storage write failed, specified area not erased.
3
Off
00
0
Flash logo area adequate, definition stored
On
08
8
Flash logo area not adequate
4
Off
00
0
Not used. Fixed to off.
5
Off
00
00
No thermal user-defined characters
written to flash.
On
20
32
Thermal user-defined characters written to flash.
6
Off
00
0
Not used. Fixed to off.
7
–
–
–
Undefined.
Exceptions
When n is out of the specified range, the command is ignored.
Send printer software version
ASCII
US V
Hexadecimal 1F 56
Decimal
31 86
The printer returns 8 bytes containing the boot and flash software version. The first 4 bytes returned are an ASCII string for
the boot version.
The second 4 bytes are an ASCII string for the flash version. Example: For 1.234.56 (8 bytes), the boot version is 1.23 and
the flash version is 4.56.