O v e r v i e w o f t h e G L X

To stop data recording, press

again.

You have just collected and graphed a run of temperature data. To collect addi-
tional data runs, press

again.

There are several different ways to collect data with the GLX. This is the sim-
plest and most common. See “F1 Mode” on page 57 for other options. You
can find a complete description of the Graph display starting on page 13.

O v e r v i e w o f t h e G L X

The example above represents just a small part of the GLX’s capabilities. This
overview will outline some of the set-up options to customize your GLX and pre-
pare it for an activity; then (starting on page 9) survey the GLX’s Home Screen
as a gateway to the entire GLX environment.

Equipment Set-up Options

Power Source

Whenever possible, it is a good idea to use the GLX connected

to the AC power supply. For maximum operating time on battery power, first
connect the GLX to AC power for at least 14 hours, or until the Battery Gauge
indicates a full charge

.

1

Power On

The power turns on automatically when you plug in the AC adapter.

If the GLX is running on batteries, or if the AC adapter is already connected,
push and hold the power button (

) for about 1 second to turn it on.

By default, the GLX is set to start with a new data file; however, if the Startup
Action of the GLX has been set to “Open Last Experiment,” it will automatically
open the most recently saved file. See page 86 for more information.

Back Light

To turn on the screen’s back light, press and hold

while you

press .

2

Screen Contrast

There are 21 levels of screen contrast. Push and hold

,

then use the up and down arrow keys (

) to adjust the contrast to a comfortable

level.

Language

In its factory configuration, the GLX is set up to operate in English.

If you would like to change the language, refer to “Settings Screen” on page 85.

PASPORT Sensors

Connect up to four PASPORT sensors to the main ports

on top of the GLX.

In some cases, the GLX may automatically launch the Graph or other display
when you plug in a sensor. See “Sensor Auto-Display” on page 86 for more
information about this feature.

Temperature Probes

Connect the included fast-response probes or other

PASCO temperature probes to the two temperature ports on the left side of the
GLX. The range is -10 to +70 °C with fast-response probes, or -10 to +135 °C
with stainless steel probes.

Voltage Probe

Connect the included voltage probe to the voltage port on the

left side of the GLX to measure voltages between -10 and +10 V. The voltage
probe should be connected to voltage sources only when it is also connected to

1

See “Battery Gauge” on page 11.

2

The backlight and other aspects of the

Xplorer GLX can also be adjusted in the
Settings Screen. See page 85.

Temperature

Probes

Signal

Output

PASPORT

Sensor Ports

Voltage

Probe

Security Cable

Connection Slot