Parts List

C.SXR−2
Foot Control, 230V

FOREDOM

The Foredom Electric Company

16 Stony Hill Rd., Bethel, CT 06801

203−792−8622

Fax: 203−796−7861

www.foredom.net

}

Qty

Description

Part No.

Item

1

Cover

CP10691

1

1

Trigger Switch, 250V

CP11027

2

2

Screw, 6−32 X 5/16"

CP10571

3

1

Circuit Board, SXR

CP10874

4

1

Base

CP10690

5

1

Base Pad

CP10753

6

1

Male Cordset or Substitute Option

CP10541

7

2

Hinge Pin

CP10584C

8

1

Grommet

CP10578

9

1

Female Cordset

CP10868

10

1

Lock Washer, #8

CP10564

11

1

Ring Terminal

CP10580

12

1

Screw, 8−32 x 1/4"

CP10563

13

3

2 Wire Connector

CP11029

14

1

Set Screw

CP10562

15

1

Spring

CP10588

16

Attach

Ground Screw

to Base

Board

AC Male Plug

to Power Source

Wiring Diagram

BLK

BRN

WHT

W

H

T

(B

LU

)

BLK

GRN

(GRN/YLW)

GRN/YLW

WHT

BLK

Form DN 12/10

Female Receptacle

to Motor

2

5

4

3

6

1

Trigger

Switch

Board

Part No.

Cordset Option

Description

CPOption20 CP10545 No Plug, Europe
CPOption21 CP10553 Male, United Kingdom
CPOption22 CP10554 Male, Continental Europe
CPOption25 CP10555 Male India 10A
CPOption26 CP10556 Male, Austrailia

Position wires around post of Base so wires will not

interfere with Cover travel.
Install Cover over Spring (16) and align holes to Base.

Insert Pins (8) and seat them with hammer.

9.

8.

Install Board and Switch into Base using two Screws (3).

Connect Wires to New Trigger Switch as shown in the

Wiring Diagram.

Push wires all the way in, so that no bare wire

is exposed. On Screw Terminal 1, push the wire lead all the way

into the socket then tighten the screw firmly. Push the other

wire lead all the way into terminal 6. Pull on all the wires, making

sure they are secure.

6.

5.

On older Switches, all the terminals will be push-in, spring clamp

type. On newer Switches, Terminal 1 has a screw for fastening

the wire lead. To remove wires from the push-in terminals, insert

1.3mm [.05in] approximate diameter pin or the blade of a jeweler's

screwdriver all the way into the terminal socket to release the

spring clamp. Grasp the tool and wire and pull them together out

of the socket. If you have difficulty removing the wires from the

push-in terminals and you have wire-cutting, stripping, and

soldering tools, you can cut the wires off where they exit from the

terminals. To prepare the cut wires for installation into the

replacement Switch, strip them back exactly 8.25 mm [5/16 in],

then apply solder to the stripped ends to fuse the strands together.

Remove two Screws (3) from Board (4). After the wires have

been removed from the switch, as instructed in paragraph 4,

remove the switch from the board, insert the new switch in its

place, and follow the instructions in paragraph 5 and 6.

Insert new Trigger Switch into Board.

7.

Remove Cover and drive Pins outward with hammer and punch

to remove.

With a punch and hammer drive two Pins (8) in until Cover (1)

lifts from each side of Base (5).

Disconnect Foot Control from Motor and Wall Outlet.

Instructions for Removing
and Replacing Trigger Switch

1.

3.

2.

4.

For use with LX 230V Motors
and discontinued TX 230V Motors.

4

3

5

6

7

9

8

11

12

13

16

Wire
Connectors

1