Foredom C.TXR-2CE User Manual

Parts list, Foredom, C.txr−2ce foot control, 230v

Advertising
background image

Disconnect Foot Control from Motor and Wall Outlet.

2.

1.

Insert adjustment screw (8) through washer (9) and into post

slot and threaded insert in cover (1). Tighten with screwdriver

until cover is just touching the trigger switch pushrod. Do not

tighten the screw further

to avoid pressing the Switch Pushrod

into a permanently "on" position.

Connect Wires to New Trigger Switch as shown in the

Wiring Diagram.

Push wires all the way in, so that no bare wire

is exposed. On Screw Terminal 1, push the wire lead all the way

into the socket then tighten the screw firmly. Push the other wire

lead all the way into terminal 6. Pull on all the wires, making sure

they are secure. Place Switch back into Base mounting bracket.

Position wires around adjustment screw post so wires will not

interfere with cover travel.
Snap cover (1) onto hinge posts on top of rear corners of base (6).

Instructions for Removing
and Replacing Trigger Switch

Unscrew cover adjustment screw (8).
Using flat blade of screwdriver inserted at Point A

between Cover (1) and Base (6), carefully pry Cover off.
Remove Trigger Switch (5) from Base mounting bracket.
On older Switches, all the terminals will be push-in, spring clamp

type. On newer Switches, some terminals have screw fasteners.

To remove wires from the push-in terminals, insert 1.3mm [.05in]

approximate diameter pin or the blade of a jeweler's screwdriver

all the way into the terminal socket to release the spring clamp.

Grasp the tool and wire and pull them together out of the socket.

If you have difficulty removing the wires from the push-in terminals

and you have wire-cutting, stripping, and soldering tools, you can

cut the wires off where they exit from the terminals. To prepare

the cut wires for installation into the replacement Switch, strip

them back exactly 8.25 mm [5/16 in], then apply solder to the

stripped ends to fuse the strands together.

5.

4.

6.

7.
8.

3.

Qty

Description

Part No.

Item

1

Cover

CP10852B

1

2

Screw, 6−32 x 5/16, Slotted

CP10571

2

1

Fish Paper

CP10525

3

1

Circuit Board

CP10521

4

1

Trigger Switch, 250V

CP11027

5

1

Base

CP10851F

6

1

Front Base Pad

CP10859

7

1

Screw, 6−32 x 1"

CP10856

8

1

Washer, #6

CP10862

9

1

Rear Base Pad

CP10860

10

1

Strain Relief

CP10002

11

1

Female Cordset

CP10868

12

1

*Detachable Cordset, or Substitute Option

CP10835

13

2

Screw, 6−32 x 3/8", Flathead

MP2027

14

1

Wire, 3", Brown, Tinned

CP11163

15

1

Wire, 3", Brown

CP11162

16

1

EMI Filter

CP10879

17

CPOption26 CP10836 Detachable, Australian

*CPOption22 CP10835 Detachable, Continental Europe

CPOption21 CP10834 Detachable, United Kingdom

Cordset Option

Parts List

C.TXR−2CE
Foot Control, 230V

BLU

GRN/

YLW GRN/

YLW

BRN

BRN

BRN

BLU

5

6

1

3

4

2

Trigger

Switch

For TXR-2CE:

EMI Filter with

IEC-C14 Socket

Fe

mal
e Rec
ept

acl

e

to

Mot
or

Wiring Diagram

}

FOREDOM

The Foredom Electric Company

16 Stony Hill Rd., Bethel, CT 06801

203−792−8622

Fax: 203−796−7861

www.foredom.net

Po

we

r Inp
ut

Co

rd

se

t

1

2

3

4

5

6

7

8

9

10

12

13

11

14

17

BRN

Point A

15

16

Advertising