Foredom C.TXR-2CE User Manual
Parts list, Foredom, C.txr−2ce foot control, 230v
Disconnect Foot Control from Motor and Wall Outlet.
2.
1.
Insert adjustment screw (8) through washer (9) and into post
slot and threaded insert in cover (1). Tighten with screwdriver
until cover is just touching the trigger switch pushrod. Do not
tighten the screw further
to avoid pressing the Switch Pushrod
into a permanently "on" position.
Connect Wires to New Trigger Switch as shown in the
Wiring Diagram.
Push wires all the way in, so that no bare wire
is exposed. On Screw Terminal 1, push the wire lead all the way
into the socket then tighten the screw firmly. Push the other wire
lead all the way into terminal 6. Pull on all the wires, making sure
they are secure. Place Switch back into Base mounting bracket.
Position wires around adjustment screw post so wires will not
interfere with cover travel.
Snap cover (1) onto hinge posts on top of rear corners of base (6).
Instructions for Removing
and Replacing Trigger Switch
Unscrew cover adjustment screw (8).
Using flat blade of screwdriver inserted at Point A
between Cover (1) and Base (6), carefully pry Cover off.
Remove Trigger Switch (5) from Base mounting bracket.
On older Switches, all the terminals will be push-in, spring clamp
type. On newer Switches, some terminals have screw fasteners.
To remove wires from the push-in terminals, insert 1.3mm [.05in]
approximate diameter pin or the blade of a jeweler's screwdriver
all the way into the terminal socket to release the spring clamp.
Grasp the tool and wire and pull them together out of the socket.
If you have difficulty removing the wires from the push-in terminals
and you have wire-cutting, stripping, and soldering tools, you can
cut the wires off where they exit from the terminals. To prepare
the cut wires for installation into the replacement Switch, strip
them back exactly 8.25 mm [5/16 in], then apply solder to the
stripped ends to fuse the strands together.
5.
4.
6.
7.
8.
3.
Qty
Description
Part No.
Item
1
Cover
CP10852B
1
2
Screw, 6−32 x 5/16, Slotted
CP10571
2
1
Fish Paper
CP10525
3
1
Circuit Board
CP10521
4
1
Trigger Switch, 250V
CP11027
5
1
Base
CP10851F
6
1
Front Base Pad
CP10859
7
1
Screw, 6−32 x 1"
CP10856
8
1
Washer, #6
CP10862
9
1
Rear Base Pad
CP10860
10
1
Strain Relief
CP10002
11
1
Female Cordset
CP10868
12
1
*Detachable Cordset, or Substitute Option
CP10835
13
2
Screw, 6−32 x 3/8", Flathead
MP2027
14
1
Wire, 3", Brown, Tinned
CP11163
15
1
Wire, 3", Brown
CP11162
16
1
EMI Filter
CP10879
17
CPOption26 CP10836 Detachable, Australian
*CPOption22 CP10835 Detachable, Continental Europe
CPOption21 CP10834 Detachable, United Kingdom
Cordset Option
Parts List
C.TXR−2CE
Foot Control, 230V
BLU
GRN/
YLW GRN/
YLW
BRN
BRN
BRN
BLU
5
6
1
3
4
2
Trigger
Switch
For TXR-2CE:
EMI Filter with
IEC-C14 Socket
Fe
mal
e Rec
ept
acl
e
to
Mot
or
Wiring Diagram
}
FOREDOM
The Foredom Electric Company
16 Stony Hill Rd., Bethel, CT 06801
•
203−792−8622
Fax: 203−796−7861
•
www.foredom.net
Po
we
r Inp
ut
Co
rd
se
t
1
2
3
4
5
6
7
8
9
10
12
13
11
14
17
BRN
Point A
15
16