KB Electronics KBMK-24DF User Manual

Page 43

Advertising
background image

43

TABLE 24

ANALOG INPUT "2" ELECTRICAL RATINGS

Parameter Specification

Factory

setting

Voltage Range (Volts DC)

0 – ±2.5 thru 0 – ±25

0 – 5

MAX2 Scaling Trimpot Range (Volts DC)

0 – 24

5

Current Range (mA DC)

0 – 20*

Input Impedance for Current Mode (Ω) 270

PWM (kHz, Duty Cycle)

0.15 – 1, 0 – 100

*If using 4 – 20 mA DC signal input, the offset setting in Function No. 9.07 must be
increased from "0%" (factory setting) to "20%". Set Jumper J1 to the "CUR" position.


TABLE 25

ANALOG INPUT "2" SIGNAL CURRENT FOLLOWING PROGRAMMING

Function No.

Code/Range

2.00: Frequency Control 0003:

Analog Signal 2

9.05: Analog Input 2 Gain 0

500:

Set to the Desired Gain

7.04: Multi-Function Input Terminal 5

0010: N.O. Start*

9.06: Analog Input 2 Slope

0000: Positive
0001: Negative

9.07: Analog Input 2 Offset 0

100:

Set to the Desired Offset

9.08: Analog Input 2 Type

0000: Analog Voltage or Current

9.09: Analog Input 2 Response Time (mSec) 2 – 100: Set to the Desired Time

*Factory setting.


FIGURE 33

ANALOG INPUT "2" SIGNAL CURRENT FOLLOWING CONNECTIONS

MAX2 Trimpot

and Jumper J1


+




A9. ANALOG SIGNAL OUTPUT

Two analog signal outputs are provided, which will linearly follow the parameter programmed in Analog output
1 Mode (Function No. 8.06) and Analog Output 2 Mode (Function No. 8.08). They can be used to monitor
Motor Frequency, Set Frequency, Motor Voltage, Bus Voltage, and Motor Current. See Figure 34, on page
44, for Analog Output 1 and 2 Gain settings (factory set to 100%). See Table 26, for Analog Outputs 1 and 2
electrical ratings. See Table 27, on page 44, for drive programming. See Figure 35, on page 44, for
connections.

Analog Output 1 provides a voltage signal output. Analog Output 2 provides a voltage or current signal output.

TABLE 26

ANALOG OUTPUTS "1" AND "2" ELECTRICAL RATINGS

Parameter Specification

Factory

setting

Analog Outputs 1 and 2 Voltage Range (Volts DC)

0 – 5

0 – 5

Analog Output 2 Current Range (mA DC)

0 – 20, 4 – 20

Analog Output 2 Impedance for Current Mode (Ω)

150 –