Southern Folger 3150LX.b ELECTRIC LOCKING SYSTEMS User Manual

3150lx.b electric locking systems, 3150lx.b electric locking system, Function

Advertising
background image

FOR MORE INFORMATION, PLEASE CALL 210-533-1231

Revised 3/09

3150LX.b ELECTRIC
LOCKING SYSTEM

The 3150LX.b system offers com-
plete selective electric operation of
sliding doors in a line or group from
a remote control station. Doors are
operated by electric motors through
a rack and pinion drive mechanism
over each door. This system also
provides emergency mechanical
unlocking from a control cabinet at
the head of the door line. Doors are
locked at top and bottom in both the
open and closed positions by means
of a concealed vertical lock bar at
the rear jamb of each door. The
vertical lock bar is deadlocked at a
third locking point inside the
horizontal cover box above the door.
Standard clear door opening widths
are from 2'4" to 3'2".

FUNCTION:

ELECTRIC - A remote switch
activates a motor which raises a
vertical lock bar and propels the
door open or closed. Individual lamp
indicators on the control panel show
locked/unlocked condition. A single
switch can provide group unlocking.

MECHANICAL -

In the absence of

electrical power, doors may be
individually unlocked with a manual
release tool. Door movement is by
hand and door will relock in either
fully open or closed position.

EMERGENCY GANG RELEASE -

In

an emergency, all doors in a cell line
may be simultaneously unlocked
from a mechanical release cabinet at
the end of the cell line. While in
emergency release mode, doors will
not relock in any position.

3150LX.b

ELECTRIC LOCKING

SYSTEMS

TECHNICAL DATA:

• COVER BOX:

1' 0 - 3/4" H x 7-1/2" D

• COVER BOX MATERIAL:

7 gauge steel plate

• HINGED PANEL:

10 gauge steel

• DOOR ROLLERS:

3" diameter, machined
steel with sealed bearings

• VERTICAL LOCK BAR
• DIMENSIONS:

5/8" SQ by full height
of door

• FINISH: Prime paint
• DOOR HANGER:

7 gauge steel plate

• ELECTRICAL:

Motor: 1/20 HP, 115 VAC,
60 Hz., single phase power
Inrush: .8A
Running: .72A
Locked Rotor Current: 1.2A

• WIRE REQUIREMENTS:

When electric operation of the
door is from a remote station, a
minimum of five conductors
(minimum 14 gauge) are required
between the control point and
the door, except for those
models having the letter “K”
(keyswitch) in the suffix.
Keyswitch models require
minimum six conductors.

L O C K I N G S Y S T E M S

FOR GROUPS OF
SLIDING CELL DOORS

Maximum security.

B21

090604SouthernFolger_final:INSIDE 8/21/09 5:22 PM Page 31