8010L PNEUMATIC
LOCKING SYSTEM

For use where remote electric
unlocking of groups of sliding doors is
required, but door movement can be
by hand at the door. This system also
provides emergency pneumatic
unlocking from a remote location.
Doors are locked at top and bottom in
both the open and closed positions by
means of a concealed vertical lock bar
at the rear jamb of each door. The
vertical lock bar is deadlocked at a
third locking point inside the horizontal
cover box above the door. Standard
clear door opening widths available
are 2'4" to 3'2".

FUNCTION:

ELECTRIC - Individual switches
located on a remote control panel
actuate a pneumatic cylinder housed
in the horizontal cover box over each
door, raising the vertical lock bar and
unlocking the door. Upon unlocking,
the door springs open a few inches.
All door movement is by hand at the
door, which automatically
snap/deadlocks when moved to the
fully closed or fully open position.
Individual lamp indicators on the
control panel show locked/unlocked
condition. A single switch can provide
group unlocking.

MECHANICAL - In the absence of
pneumatic or electrical power, doors
may be individually unlocked with a
manual release tool. Door movement
is by hand and door will relock in either
fully open or closed position.

EMERGENCY GANG RELEASE -
In an emergency, all doors in a cell line
may be simultaneously unlocked from
a remote location using a pneumatic
release system. While in emergency
release mode, doors will not relock in
any position.

8010L

PNEUMATIC

LOCKING SYSTEM

TECHNICAL DATA:

• COVER BOX:

1' 0-3/4" H x 7-1/2" D

• COVER BOX MATERIAL:

7 gauge steel plate

• HINGED PANEL:

10 gauge steel

• DOOR ROLLERS:

3" diameter, machined
steel with sealed bearings.

• VERTICAL LOCK BAR

DIMENSIONS:
5/8" SQ by full height
of door.

• FINISH: Prime paint
• DOOR HANGER:

7 gauge steel plate

• ELECTRICAL: 24 VDC

Minimum five 24 volt conductors
are required between the
control point and the door,
except for those models
having the letter “K”
(keyswitch) in the suffix.
Keyswitch models require
minimum six conductors.

• AIR REQUIREMENTS:

Air consumption 1.9 cubic
inches per unlock operation at
80 PSIG.

L O C K I N G S Y S T E M S

FOR GROUPS OF
SLIDING CELL DOORS

Maximum security.

C7