Set R/S Time Base
Use This menu to set the global ramp and soak time base to units of
hours and minutes or minutes and seconds. All time entries in r/s
profiles will assume the units you set here.
Selectable values: Hours and minutes or minutes and seconds.
NOTE
This prompt appears only if your 8LS has the
Ramp and Soak option installed.
Lock Panel
Use this menu to disable the front panel keys Chng SP, Man/Auto, and
Ramp/Soak.
Selectable values: On or Off.
Power Up Output Status
Use this menu to configure the initial power-up state of the control
outputs. If you choose Off, all control outputs are initially set to Manual
mode at 0% output level. If you choose Mem, the outputs are restored to
their condition when power was removed.
Selectable values: Off and Mem.