4 connecting the recorder and the pc, 4 connecting the recorder and the pc -4 – Yokogawa µR20000 User Manual

Page 12

Advertising
background image

1-4

IM 04P01B01-61E

1.4 Connecting the Recorder and the PC

Using the Ethernet Communication Interface (/C7 Option)

For the procedure to connect the recorder and the PC, see section 2.2, “Connecting the
Ethernet Interface” in the µR10000/µR20000 Communication Interface User’s Manual (IM
04P01B01-17E).

Using the RS-422/485 Communication Interface (/C3 Option)

For the procedure to connect the recorder and the PC, see section 3.2, “Terminal
Arrangement and Signal Names and the Connection Procedure of the RS-422/485
Communication Interface” in the µR10000/µR20000 Communication Interface User’s
Manual (IM 04P01B01-17E).

Using the Interface Unit (For the RXA10-02)

CAUTION

Do not insert or remove the interface unit while the recorder is turned ON. If you do,
the internal circuit of the recorder and/or the interface unit may be damaged.

Note

• When using the interface unit, turn OFF the device that is connected to the RS-422/485

communication interface (/C3 option) on the recorder rear panel or disconnect the cable.
Data may be sent to the device connected to the RS-422/485 communication interface on
the rear panel when the interface unit is communicating.

• Use a D-Sub 9-pin RS-232 cable (cross cable) to connect the PC and the interface unit (The

connector on the interface unit is a D-Sub 9-pin plug (male)).

1 2 3 4 5

6 7 8 9

Interface unit (D-Sub 9-pin plug)

Pin

Assignments

1

CD

Carrier Detect

2

RXD

Receive Data

3

TXD

Transmit Data

4

DTR

Data Terminal Ready

5

GND

System Ground

6

SDR

Data Set Ready

7

RTS

Request to Send

8

CTS

Clear to Send

9

RI

Ring Indicator

Pins 4 and 6 are shorted internally.
Pins 7 and 8 are shorted internally.