Brocade 6505 default policy, Implementing your switch status policy, Viewing your switch status policy – Brocade Fabric Watch Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 94

Advertising
background image

NOTE
The presence of four or more FS8-18 encryption blades in the DCX Data Center Backbone causes the
Fabric Watch switch status policy for power supplies to assume a policy setting of 2,1.

Brocade 6505 default policy

The default Fabric Watch policy for the Brocade 6505 is one power supply in the left bay with an
optional configuration of two power supplies in both the left and right bays. The default configuration
for the Brocade 6505 is a 2 (DOWN) and 0 (MARGINAL), corresponding to a one power supply
configuration. If converting to a two power supply configuration, use the switchStatusPolicySet
command to manually change the configuration to 2,1 for the power supply and fan FRU units. If
converting back to a one power supply configuration, use the switchStatusPolicySet command to
manually change the power supply and fan FRU units to 1,0.

Implementing your switch status policy

After you plan and define your switch status policy, implement it using the following procedure.

1. Enter the switchStatusPolicySet command to configure each policy.

Each policy has two parameters that can be configured: Marginal and Down.

2. Set the number of units Marginal or Down based on your system requirements for each policy or

parameter.

NOTE
Switch status policies are saved in a nonvolatile memory, and therefore are persistent until
changed.

The following example shows a switch status policy for temperature:

Bad Temperatures contributing to DOWN status: (0..10) [0] 3

Bad Temperatures contributing to MARGINAL status: (0..10) [0] 1

The following example shows a switch status policy for fans:

Bad Fans contributing to DOWN status: (0..3) [0] 2

Bad Fans contributing to MARGINAL status: (0..3) [0] 1

Viewing your switch status policy

After you have defined and configured your switch status policy, view it with the
switchStatusPolicyShow command. The switchStatusPolicyShow command displays the following
policy parameters that determine the overall switch status:

NOTE
FCoE and VE_Ports are not considered in marginal port or faulty port calculations.

• Power Supplies — The power supply thresholds detect absent or failed power supplies.
• Temperature — Temperature thresholds detect faulty temperature sensors.
• Fan — Fan thresholds detect faulty fans.

Brocade 6505 default policy

94

Fabric Watch Administrators Guide

53-1003142-01