RIKON Power Tools 50-110 User Manual
Page 7
7
Leveling Table Assembly
1. Place a combination square on the Table (35)
so that it also touches the sanding Disc (27).
(See Fig. 08)
If the Table is 90 degrees to the Disc, no
adjustments are needed.
2. If the Table is not 90 degrees with the Disc,
loosen the table lock Knob (1) and tilt the Table
until the square is flush with the Disc.
3. Retighten the Knob to secure the table.
4. Attach the scale label (37) to the “0” degrees
mark on the dust guard (34).
Installing and Adjusting the Sanding Belt
*Belt table must be in the vertical position.
1. Move Tension Lever (66) to the right to release
the Sanding Belt (10) tension. (See Fig. 09)
2. Place the Sanding Belt over the Drive and Idler
Drums (13 and 65). (See Fig. 10)
Make sure that the inside direction arrows point
down, towards the Drive Drum (13). (See Fig. 11)
3. Center Belt on both drums.
4. Slide Tension Lever (66) to the left to tighten
belt
tension.
5. Tighten Hex Socket Screw (56) when Bed (4)
is
in desired working position.
6. Plug the Power Cord (38) into the wall outlet.
Turn the power Locking Switch (22) On, and the
off
while viewing the belt movement. If the belt looks
like it was going to slide off either drum, the belt
racking needs to be adjusted (described in the
next
step).
7. If the Sanding Belt (10) moves towards the
Fig. 08
Fig. 09
Fig. 10
Fig. 11