Installation – KROHNE OPTIWAVE 5200 C_F EN User Manual

Page 28

Advertising
background image

3

INSTALLATION

28

OPTIWAVE 5200 C/F

www.krohne.com

07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en

Equipment needed:

• Device
• Flange gasket (not supplied)
• Wrench (not supplied)

• Make sure the flange on the nozzle is level.
• Make sure that you use the applicable gasket for the flange dimensions and the process.
• Align the gasket correctly on the flange facing of the nozzle.
• Lower the antenna carefully into the tank.
• Make sure that you point the device in the correct direction. Refer to "Point the device in the

correct direction" in this section.

• Tighten the flange bolts.

i

Refer to local rules and regulations for the correct torque to apply to the bolts.

Requirements for flange connections

Figure 3-14: Flange connection

Advertising