Milestone Basis+ 6.5 User Manual
Page 97
Milestone XProtect Basis+ 6.5; Administrator’s Manual
This will open the Output Settings for [Device Name] [Camera Name] window (see page
88).
7. In the All Outputs list in the window’s left side, select the required output, then click the
>> button located between the All Outputs list and the On Manual Control list:
This will copy the selected output to the On Manual Control list, which lists all outputs
available for manual control when viewing live video from the camera in question.
Good to know:
•
You are not limited to selecting output connected to the camera itself. If output has
been defined on other cameras/devices on the XProtect Basis+ system, this output
will also be selectable in the All Outputs list.
•
An unlimited number of outputs may be selected this way.
•
If you have specified several outputs in the On Manual Control list, you are able to
control the sequence in which the outputs will be displayed in the Remote Client
(see page 142) and Smart Client (see page 140). By using the up and down
buttons located to the right of the list, you can change a selected output’s position
in the sequence.
•
The Output Settings for [Device Name] [Camera Name] window (see page 88) also
lets you select output for automatic triggering on detected motion. This is further
www.milestonesys.com
Page 97
Input, Events & Output