HP Storage Essentials NAS Manager Software User Manual

Page 332

Advertising
background image

Provisioning Manager

302

*Also applies to EMC Connectrix switches.
**Also applies to Sun StorEdge SNMP switches.
***SANbox-2 only
Issues for Sun StorEdge and QLogic SNMP (Simple Network Management Protocol) switches:

Active zoning is not reported for Sun StorEdge and QLogic switches that have the SNMPv1

Agent. Switches that do report active zoning, do not supply information about inactive zones to

the management server.

If a zone alias for a Sun StorEdge or QLogic switch is a member of an active zone, the zone

alias is not shown in the user interface, but its members are displayed as belonging to the active

zone.

Issues for Cisco SNMP and SMI-S (Storage Management Initiative Specification) switches:

The management server groups active zone sets in all Virtual SANs (VSANs) in a fabric into a

zone set called “ACTIVE”, and the “ACTIVE” zone set is shown associated with the physical

fabric. The members of the “ACTIVE” zone set (zones, zone sets, zone aliases) have the name of

the VSAN prefixed to their name. For example, an active zone named “ZONE1” from a VSAN

named “VSAN1” is displayed as a zone on the physical fabric with name “VSAN1:ZONE1”.

Cisco SMI-S switches:

You can view and create zones, zone sets and zone aliases on a Cisco SMI-S switch.

Cisco SNMP switches:

You can view zones, zone sets and zone aliases on a Cisco SNMP switch; however, you cannot

use the management server to create, modify or remove them from a Cisco switch.

Issues for McDATA and Connectrix switches:

*McDATA

SNMP to

switches

Y

N

N

N

Y

Cisco SNMP

Y

N

Y

N

Y

Cisco SMI-S

Y

Y

Y

Y

Y

CNT SMI-S

Y

Y

N

N

Y

**QLogic

SNMP

Y***

N

N

N

Y

**QLogic

SMI-S

Y

Y

Y

Y

Y

Table 46

Zoning Support

Switch

Type

Active

Zones

Inactive

Zones

Aliases

Zone/Zone Set

Provisioning

Port

Statistics

Advertising