Front panel leds and buttons – HP 9000 Virtual Library System User Manual
Page 194
Front Panel LEDs and Buttons
Status
Description
Item
Dual-function momentary switch. Its purpose is to reset the switch or to place the
switch in maintenance mode.
Maintenance button
1
To reset the switch, use a pointed tool to momentarily press and release (less than
2 seconds) the Maintenance button. The switch will respond as follows:
1.
All the chassis LEDs will illuminate except the System Fault LED.
2.
After approximately 1 minute, the power-on self test (POST) begins, extinguishing
the Heartbeat LED.
3.
When the POST is complete, the Input Power LED is illuminated and the
Heartbeat LED is flashing once per second.
Green = Switch logic circuitry is receiving the proper DC voltages.
Input power LED
2
Off = Switch is in maintenance mode.
Green = Switch is in maintenance mode.
Heartbeat LED
3
Blinking green (constant 1 Hz) = Switch passed the POST and the internal switch
processor is running.
2 blinks = Internal firmware failure.
3 blinks = System error.
4 blinks = Configuration file system error.
5 blinks = Over temperature.
See
for more information.
Amber = A fault exists in the switch firmware or hardware. Fault conditions include
POST errors and over temperature conditions.
System fault LED
4
Off = Switch is operating normally.
Green = Data is being transmitted or received over the Ethernet connection.
Ethernet port activity
LED
5
Off = No data being transmitted or received.
Green = Ethernet connection has been established.
Ethernet port link
status LED
6
Off = No connection.
Green = A device is logged in to the port.
Port logged-In LED
7
Flashing green (constant 1 Hz) = A device is logging in to the port.
Flashing green (constant 2 Hz) = The port is down, offline, or an error has occurred.
Green = Data is passing through the port. Each frame that the port transmits or
receives causes LED to illuminate for 50 milliseconds.
Port activity LED
8
194