Configuring iLO 2 41
Parameter
Default value Descriptions
Lights-Out
Functionality
Enabled
This setting enables connection to iLO 2. If disabled, all
connections to iLO 2 are prevented.
The iLO 2 10/100 network and communications with
operating system drivers are turned off if Lights-Out
functionality is disabled. The iLO 2 Diagnostic Port for an HP
ProLiant BL p Class server is also disabled.
If iLO 2 functionality is disabled (including the iLO 2
Diagnostic Port), you must use the server's Security Override
Switch to enable iLO 2. See your server documentation to
locate the Security Override Switch and set it to override.
Power up the server and use the iLO 2 RBSU to set Lights-Out
Functionality to Enabled.
iLO 2 ROM-Based
Setup Utility
Enabled
This setting enables or disables the iLO 2 ROM-Based Setup
Utility. Normally, the iLO2 Option ROM prompts you to press
F8 to enter RBSU, but if iLO 2 is disabled or iLO 2 RBSU is
disabled, the RBSU prompt is bypassed.
Require Login for iLO
2 RBSU
Disabled
This setting enables RBSU access with or without a user-
credentials challenge. If this setting is Enabled, and you press
F8 during POST to enter iLO 2 RBSU, a login dialog box
appears.
Show iLO 2 during
POST
Disabled
This setting enables the display of the iLO 2 network IP
address during the host server POST process.
Serial Command Line
Interface Status
Enabled-
Authentication
Required
This setting enables you to change the login model of the CLI
feature through the serial port. The following settings are
valid:
•
Enabled—Authentication Required
•
Enabled—No Authentication
•
Disabled
Serial Command Line
Interface Speed
9600
This setting enables you to use the serial port to change the
speed of the serial port for the CLI feature. The following
speeds (in bits/s) are valid: 9600, 19200, 38400, 57600,
and 115200. The serial port configuration must be set to No
parity, 8 data bits, and 1 stop bit (N/8/1) for proper
operation. The serial port speed that is set by this parameter
must match the speed of the serial port set in the System ROM
RBSU setup.
Minimum Password
Length
8
This setting specifies the minimum number of characters
allowed when a user password is set or changed. The
character length can be set at a value from 0 to 39.