Table 49 truecopy device sims, 49 truecopy device sims, Table 49 – HP StorageWorks XP Remote Web Console Software User Manual

Page 189

Advertising
background image

Hitachi TrueCopy for z/OS user guide 189

This SIM is not reported to the host system when the Service SIM=Not Report RCU option is selected.

Table 49

TrueCopy device SIMs

Ref. Code Severity

Description

Reported

to Host

Generated by Log File

22

23

D0

0x

Service

TC390 started the initial copy for this

volume, or was out of sync for this volume.

Yes

1

Once

MCU

SSB Log

D0

D8

1x

Service

TC390 completed the initial copy for this

volume.

Yes

1

Once

MCU

SSB Log

D0

2x

Service

TC390 for this volume was deleted as

requested by the XP Command View

Advanced Edition Software server, XP

Remote Web Console, SVP, or host.

Yes

1

Once

MCU

SSB Log

D0

3x

Service

The MCU changed the volume pair status as

requested by the XP Command View

Advanced Edition Software server, XP

Remote Web Console, SVP, or host.

Yes

1

Once

MCU

SSB Log

D1

sx

Service

Status of the R-VOL has changed as

requested by the MCU. The third digit of the

reference code “s” indicates change of

states as follows:
0: from simplex to pending
1: from simplex to duplex
2: from pending to duplex
3: from pending to suspended
4: from duplex to suspended
5: from duplex to simplex
6: from pending to simplex
7: from suspended to simplex
8: from suspended to pending.

Yes

1

Once

RCU

SSB Log

D2

0x

Service

The RCU changed the R-VOL status to

suspended

as requested by XP Command

View Advanced Edition Software server, XP
Remote Web Console, SVP, or host.

No

RCU

SSB Log

D2

1x

Service

The R-VOL status changed from

suspended

to

simplex

as requested by XP Command

View Advanced Edition Software server, XP
Remote Web Console, SVP, or host.

No

RCU

SSB Log

D2

2x

Service

The R-VOL status has changed from

duplex

to simplex.

No

RCU

SSB Log

D2 3x

Service

The TC390 R-VOL status has changed

from pending duplex

to simplex.

No

RCU

SSB

Log

D4

0x

Serious

TC390 for this volume was suspended due

to a failure on the remote copy connection.

Yes

2

Repeat

MCU

SIM Log

D4

1x

Serious

TC390 for this volume was suspended due

to a failure on the M-VOL or remote copy.

Yes

2

Repeat

MCU

SIM Log

D4

2x

Serious

TC390 for this volume was suspended due

to a failure on the R-VOL.

Yes

2

Repeat

MCU

SIM Log

Advertising