65 syntax requirements for optional parameters – HP StorageWorks XP Remote Web Console Software User Manual
Page 209
Hitachi TrueCopy for z/OS user guide 209
The XP12000/XP10000 will run the script commands based only on what has been specified in the text of
the script. The following table describes the syntax requirements that will be evaluated.
Table 65
Syntax requirements for optional parameters
Parameter
Syntax Requirements
Length
Check that each line does not exceed the maximum length for a script statement.
Phrases in a script
statement
A phrase is enclosed by the quotation symbols.
Use of the parentheses is correct and the number of parentheses is exact.
A statement does not terminate with an equal sign.
The parameter identification name (phrase beginning with “$”) is always defined.
The work variable and reserved variable (phrase beginning with “_”) are always
defined.
Script statement
The first line begins with (Start) as an execution statement.
The lead of one line in the execution statement always begins with a macro name or
an identification name for non-list type work variable.
Substitute statement
The number of phrases is correct.
The equal sign is described exactly between the right side and the left side.
The right side of the substitute statement is correct.
SetList, AddList
The number of phrases is not less than the minimum count.
Duplicate parameter identification names are not specified.
The required parameter identification name is defined.
The equal sign is described between the right side and $D.
Specifying the right side is correct.
The equal sign is described between the right side and $S.
Specifying the right side is correct.
The parameter identification name is described immediately after the macro.
The parameter identification names are delimited by a comma (,).
An illegal phrase is not included in any statement.
Start
The number of phrases is not fewer than the minimum count.
Duplicate parameter identification names are not specified.
The required parameter identification name is defined.
The equal sign is described between the right side and $Script.
Specifying the right side is correct.
The equal sign is described between the right side and $Svr.
Specifying the right side is correct.
The parameter identification name is described immediately after the macro.
The parameter identification names are delimited by a comma (,).
An illegal phrase is not included in one statement.
End
Check that the number of phrases matches.
Delay
The number of phrases matches.
The required parameter identification name is defined.
The equal sign is described between the right side and $Time.
Specifying the right side is correct.