System Wiring

PF 3000 Pro

Ag Leader Technology

July 2003

7-14

Checking Header
Sensor
Connections

To check the header sensor for electrical connection, use an ohmmeter and
check for the following resistance’s:

Check at:

Pins

Ohms

Cab Cable (rectangular 25 pin conn.)

11 + 18

100-200

Cab Cable (rectangular 25 pin conn.)

10 + 18

700-1000

Cab Cable (rectangular 25 pin conn.)

10 + 11

1000

Distribution Cable (large round 24 pin conn.)

10 + 16

100-200

Distribution Cable (large round 24 pin conn.)

9 + 16

700-1000

Distribution Cable (large round 24 pin conn.)

9 + 10

1000

Header Sensor Cable (rectangular 3 pin conn.)

A + B

100-200

Header Sensor Cable (rectangular 3 pin conn.)

B + C

700-1000

Header Sensor Cable (rectangular 3 pin conn.)

A + C

1000

Checking Flow
Sensor
Connections

To check the flow sensor for electrical connection, use an ohmmeter and
check for the following resistance’s (readings can be 1-3 ohms off and still
be good readings):

Check at:

Pins

Ohms

Cab Cable (rectangular 25 pin conn.)

9 + 21

350

Cab Cable (rectangular 25 pin conn.)

8 + 22

375

Distribution Cable (large round 24 pin conn.)

8 + 19

350

Distribution Cable (large round 24 pin conn.)

7 + 20

375

Flow Sensor Ext. Cable (round 9 pin conn.)

2 + 3

350

Flow Sensor Ext. Cable (round 9 pin conn.)

1 + 4

375

Flow Sensor Cable (round 9 pin conn.)

2 + 3

350

Flow Sensor Cable (round 9 pin conn.)

1 + 4

375