Pf 3000 pro, Ag leader technology – Ag Leader PF3000Pro Harvest & Application Operators Manual User Manual
Page 276
System Wiring
PF 3000 Pro
Ag Leader Technology
July 2003
7-14
Checking Header
Sensor
Connections
To check the header sensor for electrical connection, use an ohmmeter and
check for the following resistance’s:
Check at:
Pins
Ohms
Cab Cable (rectangular 25 pin conn.)
11 + 18
100-200
Cab Cable (rectangular 25 pin conn.)
10 + 18
700-1000
Cab Cable (rectangular 25 pin conn.)
10 + 11
1000
Distribution Cable (large round 24 pin conn.)
10 + 16
100-200
Distribution Cable (large round 24 pin conn.)
9 + 16
700-1000
Distribution Cable (large round 24 pin conn.)
9 + 10
1000
Header Sensor Cable (rectangular 3 pin conn.)
A + B
100-200
Header Sensor Cable (rectangular 3 pin conn.)
B + C
700-1000
Header Sensor Cable (rectangular 3 pin conn.)
A + C
1000
Checking Flow
Sensor
Connections
To check the flow sensor for electrical connection, use an ohmmeter and
check for the following resistance’s (readings can be 1-3 ohms off and still
be good readings):
Check at:
Pins
Ohms
Cab Cable (rectangular 25 pin conn.)
9 + 21
350
Cab Cable (rectangular 25 pin conn.)
8 + 22
375
Distribution Cable (large round 24 pin conn.)
8 + 19
350
Distribution Cable (large round 24 pin conn.)
7 + 20
375
Flow Sensor Ext. Cable (round 9 pin conn.)
2 + 3
350
Flow Sensor Ext. Cable (round 9 pin conn.)
1 + 4
375
Flow Sensor Cable (round 9 pin conn.)
2 + 3
350
Flow Sensor Cable (round 9 pin conn.)
1 + 4
375