Voltage, current and freqency ranges – Outback Power Systems GVFX Series Inverter/Charger Installation Manual User Manual
Page 78
76
Single Phase
127 VAC at 60 Hz
Series Stacked
127 VAC at 60 Hz per AC output leg / 254 VAC at 60 Hz between the AC output legs
Three Phase Stacked 127 VAC at 60 Hz per AC output leg (limit three) / 220 VAC at 60 Hz between AC output legs
RECOMMENDED FX DC VOLTAGE RANGE
Note:
The last two digits in the model number designate the nominal DC voltage.
Example: GVFX3648LA =48V DC Voltage.
24V Systems
22 – 32 VDC (VDC = volts DC)
48V Systems
44 – 64 VDC
MAXIMUM DC INPUT CURRENT
Note:
This is the maximum DC current the FX will draw from the battery when starting very large AC loads.
It is not used for sizing the DC disconnect or selecting DC cable gauge. It is used to select the minimum
reasonable battery capacity.
24V FXs
300 ADC per FX (ADC = amps DC)
48V FXs
150 ADC per FX
Note:
This is the maximum continuous DC current that the FX will draw from the batteries when inverting.
GTFX2524LA
125 ADC (ADC = Amps DC)
GTFX3048LA
75 ADC
GVFX3524LA
175 ADC
GVFX3648LA
90 ADC
AC INPUT OPERATING VOLTAGE RANGE
Note:
If the AC input source is out of the range noted below, the FX will not connect or stay connected.
All LA Series Inverter/Chargers
100 – 140 VAC (VAC = volts AC)
AC INPUT FREQUENCY RANGE
Note: If the AC input source is out of the range noted below, the FX will not connect or stay connected.
All LA Series Inverter/Chargers
58 - 62 Hz
VOLTAGE, CURRENT AND FREQENCY RANGES
SPECIFIED AC OUTPUT VOLTAGE OF AN LA SERIES GRID-INTERACTIVE SYSTEM
RATED DC INPUT CURRENT