Festo Контроллер позиционирования CPX-CMPX User Manual

Page 172

Advertising
background image

B. Parameters and data of the CPX terminal

B−18

Festo P.BE−CPX−SYS−EN en 0902e

Module parameter: Input debounce time

Modules

For modules with digital inputs (see manual for the module)

Function no.

4828 + m * 64 + 1

m = module number (0 ... 47)

Description

Determines when a change of edge of the sensor signal on this module is to be
accepted as a logical input signal.

Bit

Bits 4, 5

Typical values

Bit 5 4

0 0
0 1
1 0
1 1

Input debounce time
Description
0.1 ms
3 ms (typical presetting)
10 ms
20 ms

[Debounce time]

Note

Input debounce times are specified in order to eliminate interfering changes of
signal edge during switching procedures (bouncing of the input signal). Further
information on this parameter can be found in section C.1.

Tab. B/14: Input debounce time

Advertising