Festo Контроллер позиционирования CPX-CMPX User Manual

Page 53

Advertising
background image

2. Assembly

2−9

Festo P.BE−CPX−SYS−EN en 0902e

1

Tie rod

2

Loosened module

1

2

A

Fig. 2/3:

Dismantling a module or interlinking block

7. Carefully remove the loosened module by lifting it upĆ

wards.

Assembly

To insert a module or interlinking block, proceed as follows:

1. Insert the module in the desired position (see Fig. 2/3).

The tie rod must lie exactly over the tie rod groove.

Caution
When interlinking blocks are arranged in series:
Make sure that the electric plug connectors of the inter−
linking blocks are

not bent.

2. Align the CPX terminal on a flat surface so that the compoĆ

nents are not offset. Use the bearing surface for the H−rail
to align the component correctly. It is easier to align if you
use an H−rail. Alternatively, you can place the CPX terĆ
minal without pneumatics or with the CPA pneumatics in
such a way that the interlinking blocks’ electrical connecĆ
tions are facing upwards (see Fig. 2/4). The tie rod is held
in the tie rod groove by the force due to weight.

Advertising