Attention:

v

Before

performing

any

maintenance

on

the

system,

back

up

the

data.

Follow

the

instructions

in

the

Secure

Managed

Client

-

Storage

Array

User

Guide

User

Guide

for

turning

off

the

system.

v

Prior

to

removing

a

PSU

from

the

enclosure

and

to

ensure

the

system

has

warning

of

an

imminent

power

shutdown,

disconnect

power

to

the

PSU

by

either

turning

off

the

main

switch

(where

present)

or

physically

removing

the

power

cord.

v

The

storage

system

must

be

turned

off

if

replacing

a

failed

PSU

in

a

single

non-redundant

power

supply

system.

1.

Observe

all

safety

and

ESD

precautions

in

the

Safety

and

Warranty

Guide.

2.

For

non-redundant

power

supply

systems

only,

turn

off

the

storage

system.

See

the

Secure

Managed

Client

-

Storage

Array

User

Guide

for

instructions

on

turning

off

the

system.

3.

Turn

off

and

disconnect

the

power

supply

bail.

Disconnect

the

power

supply

cord

to

the

faulty

PSU.

4.

Press

the

locking

tab

to

the

left.

5.

Pull

the

handle

to

remove

the

PSU

from

the

mounting

cage.

Figure

6.

Unlatching

a

power

supply

unit

Chapter

3.

Hardware

installations

and

upgrades

11