CHAPTER 3

Installing the RTU

15

on your application. Put a plastic cap on top of the rod to
protect it.

4.

Using a ring clamp, fasten the solar panel onto the aluminum
rod. Ensure that the panel is facing south (north if you are
located in the southern hemisphere) and out of the way of the
addIT RTU.

Note: The solar panel can be mounted under or behind the addIT

RTU, but be sure that the RTU does not shadow the panel.

5.

Fasten the addIT RTU to the top of the rod using another ring
clamp. Adcon recommends that you perform another
connectivity test, if you can, to check the positioning of the
device.

6.

Attach the sensors to the

I/O

connectors and the solar panel

to the

POWER

connector by turning the plugs’ fastening screws

clockwise until secure.

WARNING

If you turn the fastening screws too tightly, you could

damage the plugs.
7.

Secure the extra length of the sensor cables to the rod with
ties.

Figure 5 shows what a typical RTU field installation looks like.

Figure 5. RTU in the Field