CHAPTER 4

Using terminal commands

47

APPLIES

TO

A720B and A723, but see also the comments in “Remote” on
page 49.

D

ESCRIPTION

A complex command acting upon the I/O ports of a device.

P

ARAMETERS

A control byte specifying the command, the bit of the port the
command is acting on, and two 16-bit parameters, depending on
the control byte; for some commands, one or both of them may be
missing. However, if they are needed for a certain command but
not given, null values are implied.

The control byte’s significance is shown in Figure 14.

Figure 14. Control Byte Layout

The Port Number selects a the port that will be affected by
the command. For the A720/A723, only 0000 and 0001 are
accepted.

The Command Code specifies the operation that will be
applied to the selected port.

Table 5 shows the command codes definitions.

Command Code

Port Number

Table 5. Command Code Definitions

Code

Description

Parameters

Returns

0000

RDP – Read Data Port. This command reads the
whole 16-bit port and returns its value; the Port
Number has no significance for this command.

None

A 16-bit integer and the
result (OK or ERROR).

0001

RDDR – Read Data Direction Register. This com-
mand reads the whole 16-bit Data Direction
Register and returns its value; the Port Number
has no significance for this command.

None

A 16-bit integer and the
result (OK or ERROR).

0010

CAI – Configure the port specified by Port Num-
ber as input (acts upon the Data Direction Regis-
ter).

The port number.

Result (OK or ERROR).

0011

CAO – Configure the port specified by Port
Number as output (acts upon the Data Direction
Register).

The port number.

Result (OK or ERROR).