CHAPTER 4

Performing Advanced Functions

40

30 4 1999 14 54 55 14 38 255 255 77 0 0 89 156 126
20 0 0 0 0
3185 0
#

Notice that if you need to get data that is not the last (newest) slot
remotely from a device, the ID must be supplied twice. If you need
to get the last slot stored, you can ignore the ID and the date/time
parameters:

8300 DATA
8300 DATA
13 5 1999 19 26 36 14 38 255 255 79 0 0 87 148 149
15 0 0 0 0
3138 0

C

OMMAND

IMME

APPLIES

TO

A723

D

ESCRIPTION

Returns immediate data.

P

ARAMETERS

None.

R

ETURNS

A formatted string representing the data sampled on the input
ports.

R

EMARKS

GET only. The answer to this command is delayed with the

SST

time (see also “

SST” on page 34). The values represent the normal

DATA frame values but formatted for easy human identification.

REMOTE

No.

E

XAMPLE

IMME
16816 IMME 30 8 2001 16 15 06 13 39 0 0 127
0 0 95
0 0 0 0 0 0
2350 0
#

C

OMMAND

ROUTE

APPLIES

TO

A723

D

ESCRIPTION

Updates a routing table than will be used for remote commands
(e.g.

DATA, INFO, etc.).