IDEX Health & Science VS-606V7 Series User Manual
Page 128
128
Replacement of cooling fan
• Inverter of W-dimension (width) 2.68 inches (68mm), 5.51 inches
(140mm), 6.69 inches (170mm), and 7.09 inches (180mm).
1. Removal
(1) Press the right and left clicks of the fan
cover to direction 1, and then pull them to
direction 2 to remove the fan cover from
the inverter unit.
(2) Pull the wiring to direction 3 from the fan
cover rear face, and remove the protective
tube and connector.
(3) Open the left and right sides of the fan
cover to remove the cooling fan from
cover.
2. Mounting
(1) Mount the cooling fan on the fan cover.
The arrow mark to indicate the wind
direction of the cooling fan must be in the
opposite side to the cover.
(2) Connect the connector and mount the pro-
tective tube firmly. Mount the connector
joint section on the fan cover rear face.
(3) Mount the fan cover on the inverter. Be
sure to mount the right and left clicks of
the fan cover on the heatsink.
(4)