Cold start grid heater fuses, Unlatch and open the engine cover, Close and latch the engine cover when complete – Lull 944E-42 Operation Manual User Manual

Page 150: General maintenance

Advertising
background image

148

Model 944E

Origin 3/04

General Maintenance

Cold Start Grid Heater Fuses

The two 125 amp fuses (1) that protect the cold start grid heater are located under
the engine hood and are mounted on the lip of the engine panel.

1. Unlatch and open the engine cover.

2. To access the fuses; open the protective covers (2) from the engine panel

side. Allow the covers to rotate on the tethers on the engine side of the
holder (3).

3. Remove the two hex nuts (4) and lockwashers (5) securing the fuse (1) and

wires to the fuse holder (3). Remove the fuse and replace with a new fuse.

4. Place the new fuse and then the wires onto the studs of the holder. Secure

the fuse and wires in place with the lockwashers (5) and hex nuts (4).
Torque the hex nuts to 7-9 lb-ft (10-12 Nm).

5. Snap the protective cover back in place. Be sure the cover snaps securely

in place on the holder.

6. Close and latch the engine cover when complete.

MU5080

1

2

3

4

5

5