Table 2-3. Machine Model Default Settings Chart

Adjustment

1532E3

1932E3

2033E3

2046E3

2646E3

2658E3

DRIVE ACCELERATION

1.0 sec

1.0

sec

1.0

sec

1.0

sec

1.0

sec

1.0

sec

DRIVE DECELERATION

0.5 sec

0.5

sec

0.5

sec

0.5

sec

0.5

sec

0.5

sec

DRIVE CREEP

10%

10%

12%

12%

12%

12

%

DRIVE SPEED MAX (LOW)

70%

70

%

100

%

100

%

100

%

100

%

DRIVE SPEED MAX (HIGH)

70%

70

%

85

%

85

%

85

%

85

%

ELEVATION MAX*

25%*

25%*

30%*

30%*

37%*

36%*

POSITRAC TIME

10 sec

10 sec

10 sec

10 sec

10 sec

10 sec

HIGH DRIVE OVER CURRENT

140 amps

140 amps

140 amps

140 amps

140 amps

140 amps

HIGH DRIVE TIME OUT*

5.0 sec*

5.0 sec*

5.0 sec*

5.0 sec*

5.0 sec*

5.0 sec**

LIFT ACCEL

1.0 sec

1.0 sec

1.0 sec

1.0 sec

1.0 sec

1.0 sec

LIFT DECEL

0.0 sec

0.0

sec

0.0

sec

0.0

sec

0.0

sec

0.0

sec

LIFT CREEP

10%

10%

15%

15%

15%

15%

LIFT UP MAX

90%

90

%

100

%

100

%

100

%

100

%

DECK ACCEL

0.5 sec

0.5

sec

0.5 sec

0.5 sec

0.5 sec

0.5 sec

DECK DECEL

0.0 sec

0.0

sec

0.0

sec

0.0

sec

0.0

sec

0.0

sec

DECK CREEP

10%

10%

10%

10%

10%

10%

DECK EXTENSION SPEED MAX.

100%

100%

100%

100%

100%

100%

DECK RETRACTION MAX

80%

80%

80%

80%

80%

80%

STATIC STEER

30%

30%

30%

30%

30%

30%

STEER (DRIVE COMP)

15%

15

%

15

%

15

%

15

%

15

%

GROUND LIFT UPMAX

100%

100%

100%

100%

100%

100%

GROUND DECK IN MAX

50%

50%

50%

50%

50%

50%

GROUND DECK OUT MAX

50%

50%

50%

50%

40

%

40

%

NOTE: WARNING: Changing the machine model will set all personalities back to the factory default settings. check the

machine model adjustment chart for the correct settings for each model. if your machine does not match the
proper settings for each model, adjust the settings as necessary in accordance with the chart.

NOTE: * JLG strongly recommends that these settings not be changed. Changing these settings may adversely affect

the performance of your machine.