22 machine model default settings, Machine model default settings -27, Machine model default settings chart -27 – JLG 2658E3 Service Manual User Manual
Page 39
SECTION 2 - PROCEDURES
3120878
– JLG Lift –
2-27
2.22 MACHINE MODEL DEFAULT SETTINGS
Table 2-3. Machine Model Default Settings Chart
Adjustment
1532E3
1932E3
2033E3
2046E3
2646E3
2658E3
DRIVE ACCELERATION
1.0 sec
1.0
sec
1.0
sec
1.0
sec
1.0
sec
1.0
sec
DRIVE DECELERATION
0.5 sec
0.5
sec
0.5
sec
0.5
sec
0.5
sec
0.5
sec
DRIVE CREEP
10%
10%
12%
12%
12%
12
%
DRIVE SPEED MAX (LOW)
70%
70
%
100
%
100
%
100
%
100
%
DRIVE SPEED MAX (HIGH)
70%
70
%
85
%
85
%
85
%
85
%
ELEVATION MAX*
25%*
25%*
30%*
30%*
37%*
36%*
POSITRAC TIME
10 sec
10 sec
10 sec
10 sec
10 sec
10 sec
HIGH DRIVE OVER CURRENT
140 amps
140 amps
140 amps
140 amps
140 amps
140 amps
HIGH DRIVE TIME OUT*
5.0 sec*
5.0 sec*
5.0 sec*
5.0 sec*
5.0 sec*
5.0 sec**
LIFT ACCEL
1.0 sec
1.0 sec
1.0 sec
1.0 sec
1.0 sec
1.0 sec
LIFT DECEL
0.0 sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
LIFT CREEP
10%
10%
15%
15%
15%
15%
LIFT UP MAX
90%
90
%
100
%
100
%
100
%
100
%
DECK ACCEL
0.5 sec
0.5
sec
0.5 sec
0.5 sec
0.5 sec
0.5 sec
DECK DECEL
0.0 sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
DECK CREEP
10%
10%
10%
10%
10%
10%
DECK EXTENSION SPEED MAX.
100%
100%
100%
100%
100%
100%
DECK RETRACTION MAX
80%
80%
80%
80%
80%
80%
STATIC STEER
30%
30%
30%
30%
30%
30%
STEER (DRIVE COMP)
15%
15
%
15
%
15
%
15
%
15
%
GROUND LIFT UPMAX
100%
100%
100%
100%
100%
100%
GROUND DECK IN MAX
50%
50%
50%
50%
50%
50%
GROUND DECK OUT MAX
50%
50%
50%
50%
40
%
40
%
NOTE: WARNING: Changing the machine model will set all personalities back to the factory default settings. check the
machine model adjustment chart for the correct settings for each model. if your machine does not match the
proper settings for each model, adjust the settings as necessary in accordance with the chart.
NOTE: * JLG strongly recommends that these settings not be changed. Changing these settings may adversely affect
the performance of your machine.