JLG 680S Service Manual User Manual
Page 116
SECTION 3 - CHASSIS & TURNTABLE
3-68
– JLG Lift –
3121234
5. The shaft seal (1B) is installed over the output shaft
(1A) and into the counterbore of the hub (1G). Care
should be taken to insure the seal (1B) is being cor-
rectly installed (smooth face up and located just
flush with the counterbore face).
6. The bearing cone (1F) is an interference fit and has
to be pressed or tapped on.
7. Pipe plugs (1J & 1K) should be checked and/ or
installed at this time in the assembly.
8. Bearing spacer (1H) is installed around the output
shaft (1A) and locates on bearing cone (1F).
9. Retaining ring (1I) installed into groove provided in
the output shaft (1A). This retaining ring (1I) should
never be reused in a repair or rebuild.
EYE PROTECTION SHOULD BE WORN DURING THIS PROCE-
DURE.