Door Opening by RFID Card
Specification
Activate the door contact switch by tapping/swiping the proper RFID card on/through
the reader.
Block diagram
Entering an RFID card with the defined ID (1: Event.CardEntered) activates switch 1
(2: Action.ActivateSwitch).
Intercom settings
1: Event.CardEntered: Card=0*0000
2: Action.ActivateSwitch: Switch=1; Event=1
Alarm (Dispatching Office Call) Caused by Over 2-Min
Long Door Opening
Specification
Call the dispatching office in case the door remains open for more than 2 minutes. It is
supposed that the door opening signalling contact is connected to Input1.
Block diagram
Whenever the door opens, the rising edge on Input1 signal (1: Event.InputChanged)
calls the defined telephone number (4: Action.BeginCall) with a 120s delay (2:
Event.Delay).The call is only executed if the door remains open for more than 120 s (3:
Condition.InputState).