RAD1-42-2E Oven
Owner’s Manual
O
PERATION
Version 1
21
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
your degree of understanding of the system and your willingness to keep all parts in proper
operating condition.
Check line voltage. Voltage must correspond to nameplate requirements of motors and
controls. A wrong voltage can result in serious damage. Refer to Section 1.5.4 for more
information.
Check fresh air and exhaust openings. Do not be careless about restrictions in and around the
fresh air and exhaust openings and stacks. Refer to Sections 1.5.2 and 4.2.2 for information
on exhaust specifications and requirements. Under no condition can they be permitted to
become so filled with dirt that they reduce airflow.
An exhaust opening in the rear of the unit is covered by a hat bracket. Do not remove the hat
bracket as it protects the exhaust opening from being completely covered.
For drying ovens, open the vent to prevent buildup of moisture.
For sample heating, close the vent when no ventilation is required.
Warning!
Do not use flammable solvent or other flammable material in this
oven. Do not process closed containers of any substance or
liquid in this oven because they may explode under heat.