JUMO 709050 IPC IGBT Power Converter Data Sheet User Manual

Jumo ipc igbt power converter, With amplitude control brief description, Block diagram

Advertising
background image

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany
Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

e-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2TT, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

e-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

e-mail:

[email protected]

Internet: www.jumo.us

Page 1/12

2009-11-01/00389005

JUMO IPC
IGBT Power Converter

with amplitude control

Brief description

The JUMO IPC is a power converter for controlling heater loads that previously required a
transformer (either a variable transformer or a combination of transformer and thyristor
power converter).
Its function is that of an electronic transformer with a pulsed DC output.
It combines the advantages of a conventional variable transformer, such as amplitude
control which is the sinusoidal current loading, with the advantages of a thyristor power
switch, such as current limiting, load monitoring, subordinate control action, etc.
There is no electrical isolation between the supply voltage and the load voltage.
This power converter is employed wherever substantial resistive loads need to be
switched.
To operate the IPC, a choke and a line filter are indispensable in addition to the IPC power
converter itself. Only the chokes or line filters specified by JUMO may be used for this pur-
pose. Thanks to the amplitude control (the current drawn from the supply is always sinu-
soidal), synchronous clock controls (as for burst-firing operation) and power-factor
compensation networks (for the reactive power resulting from phase-control) are no longer
required.

Block diagram

Data Sheet 70.9050

Type 709050/X3 …

Special features

k Protective operation when power supply

operated under high resistive loads
(flicker)

k Operation of low voltage heaters

directly at the power supply
without impedance-matching trans-
former

k Minimum harmonics in the instrument

power supply and low weight
(power transformer n/a)

k Short-circuit control when switching on
k Line current in proportion to the required

power (amplitude control)

k Control independent of the heaters'

resistive characteristics

k Minimum reactive power
k Compact dimensions
k The subordinate control action U

2

, P, I

2

can be freely chosen

k Ageing process compensation

for SIC heating elements

k Indicator showing when ageing can no

longer be compensated by the voltage
reserve

1

k Resistance limitation, protection of

Molybdenum Disilicide heating ele-
ments against overheating in the upper
temperature range

1

k Integrated semiconductor fuses

to

pro-

tect the IPC in the event of an earth
short

1

1. Only for types 709050/X2 and ... /X3