VERTICAL SEAM

36

Cleat

#10-16 x 1" PHD (1'-0" o.c.)

Double Bead Tape Sealant

Vertical Seam Panel

e

ave

o

ver

o

pen

f

ramIng

Eave

All Eave flashings must be installed prior to panel installation.

1. Position and install Cleat to wall with appropriate fastener, 1'-0" o.c. Make sure Cleat allows for proper Eave attachment.

2. Install Eave flashing by sliding open hem onto Cleat and resting the Eave flashing against the substrate and fasten with

#10-16 x 1" Pancake Head Driller (4'-0" o.c.) to hold the Eave Flashing in place during installation.

3. Apply a row of Double Bead Tape Sealant along the top leg of the Eave flashing about 2" from the end.

4. Install panel by fastening through with #12-14 x 1

1

/

4

" Self Driller XL screws (see pages 34-35 for panel installation).

5. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead

of Tube Sealant between the flashings and securing with pop rivets 2

1

/

2

" o.c.

Tube Sealant
#12-14 x 1

1

/

4

" SD XL (see below)

CAUTION

Additional screws

may be required for

high snow loading

and steep slopes.

INSTALLATION NOTES

3

1

2

4

Vertical Seam Fastening Pattern

3:12 Slope