VERTICAL SEAM

Z-c

loSure

I

nStallatIon

3:12 Slope

Minimum

#10-16 x 1" PHD or

#10-12 x 1" PHW

Vertical Seam Z-Closure

Field cut and bend back 1"

Double Bead Tape Sealant

1. Place a row of Double Bead Tape Sealant across panel and over each rib approximately 4" from panel end. Before proceeding,

make sure Z-Closure placement will accommodate flashing.

2. Field cut the Z-Closure 2" longer than the panel width. Snip the top and bottom leg of the Z-Closure and bend both sides back

(as shown above).

3. Fasten through the Z-Closure, Tape Sealant, Vertical Seam panel, and substrate with (4) (#10-12 x 1" PHW for solid decking,

or #10-16 x 1" PHD for open framing).

Note: For open framing, the substrate will be the Back-up Channel shown in the details.

4. Apply a row of Double Bead Tape Sealant across the top of the Z-Closure filling any gaps or openings around the panel ribs.

This will be fastened through when the flashing is installed.

Field cut and bend back 1"

INSTALLATION NOTES